Commit 57264385 authored by Sam Calisch's avatar Sam Calisch

Update README.md

parent a176d866
Pipeline #678 canceled with stage
......@@ -2,9 +2,9 @@ This is documentation for impact testing infrastructure, intended to measure pea
The specs for the test are a mass of 7.8 kg, traveling at 1 m/s, with an circular impact area of diameter of 4 cm.
<img src='impactor/release-design.png' height=250px>
<img src='impactor/testing.jpg' height=250px>
<img src='video/tracker.png' height=250px>
<img src='impactor/release-design.png' height=220px>
<img src='impactor/testing.jpg' height=220px>
<img src='video/tracker.png' height=220px>
<a href='https://gitlab.cba.mit.edu/calischs/foam-impact/tree/master/impactor'>impactor/</a> contains design files for a release mechanism for the mass. This is built around a solenoid and a push-button quick release pin (90985A311 from McMaster-Carr).
......@@ -22,3 +22,8 @@ The specs for the test are a mass of 7.8 kg, traveling at 1 m/s, with an circula
<img src='analysis/img/asker-trajectories.png' height=300px>
<img src='analysis/img/asker-energies.png' height=300px>
I've been using this measurement device to characterize the dynamics of folded foam samples I've been producing. Below are the acceleration profiles of two folded samples compared against conventional foams.
<img src='analysis/impact-first-kiri.png' height=300px>
Markdown is supported
0% or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment