Endpoint.h 43.9 KB
Newer Older
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
/*
             LUFA Library
     Copyright (C) Dean Camera, 2009.
              
  dean [at] fourwalledcubicle [dot] com
      www.fourwalledcubicle.com
*/

/*
  Copyright 2009  Dean Camera (dean [at] fourwalledcubicle [dot] com)

  Permission to use, copy, modify, and distribute this software
  and its documentation for any purpose and without fee is hereby
  granted, provided that the above copyright notice appear in all
  copies and that both that the copyright notice and this
  permission notice and warranty disclaimer appear in supporting
  documentation, and that the name of the author not be used in
  advertising or publicity pertaining to distribution of the
  software without specific, written prior permission.

  The author disclaim all warranties with regard to this
  software, including all implied warranties of merchantability
  and fitness.  In no event shall the author be liable for any
  special, indirect or consequential damages or any damages
  whatsoever resulting from loss of use, data or profits, whether
  in an action of contract, negligence or other tortious action,
  arising out of or in connection with the use or performance of
  this software.
*/

31
32
/** \ingroup Group_USB
 *  @defgroup Group_EndpointManagement Endpoint Management
33
34
35
 *
 *  Functions, macros and enums related to endpoint management when in USB Device mode. This
 *  module contains the endpoint management macros, as well as endpoint interrupt and data
36
 *  send/recieve functions for various data types.
37
38
39
40
41
42
43
44
 *
 *  @{
 */

/** @defgroup Group_EndpointRW Endpoint Data Reading and Writing
 *
 *  Functions, macros, variables, enums and types related to data reading and writing from and to endpoints.
 */
45
 
46
47
48
49
50
/** @defgroup Group_EndpointPacketManagement Endpoint Packet Management
 *
 *  Functions, macros, variables, enums and types related to packet management of endpoints.
 */

51
52
53
54
55
56
57
58
59
60
61
#ifndef __ENDPOINT_H__
#define __ENDPOINT_H__

	/* Includes: */
		#include <avr/io.h>
		#include <stdbool.h>

		#include "../../../Common/Common.h"
		#include "../HighLevel/USBTask.h"

		#if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)
62
			#include "../HighLevel/StreamCallbacks.h"
63
		#endif
64
		
65
66
67
68
69
70
71
	/* Enable C linkage for C++ Compilers: */
		#if defined(__cplusplus)
			extern "C" {
		#endif

	/* Public Interface - May be used in end-application: */
		/* Macros: */
72
			/** Endpoint data direction mask for \ref Endpoint_ConfigureEndpoint(). This indicates that the endpoint
73
74
			 *  should be initialized in the OUT direction - i.e. data flows from host to device.
			 */
75
			#define ENDPOINT_DIR_OUT                      (0 << EPDIR)
76

77
			/** Endpoint data direction mask for \ref Endpoint_ConfigureEndpoint(). This indicates that the endpoint
78
79
			 *  should be initialized in the IN direction - i.e. data flows from device to host.
			 */
80
			#define ENDPOINT_DIR_IN                       (1 << EPDIR)
81

82
			/** Mask for the bank mode selection for the \ref Endpoint_ConfigureEndpoint() macro. This indicates
83
84
85
86
			 *  that the endpoint should have one single bank, which requires less USB FIFO memory but results
			 *  in slower transfers as only one USB device (the AVR or the host) can access the endpoint's
			 *  bank at the one time.
			 */
87
			#define ENDPOINT_BANK_SINGLE                  (0 << EPBK0)
88

89
			/** Mask for the bank mode selection for the \ref Endpoint_ConfigureEndpoint() macro. This indicates
90
91
92
93
			 *  that the endpoint should have two banks, which requires more USB FIFO memory but results
			 *  in faster transfers as one USB device (the AVR or the host) can access one bank while the other
			 *  accesses the second bank.
			 */
94
			#define ENDPOINT_BANK_DOUBLE                  (1 << EPBK0)
95
96
97
98
			
			/** Endpoint address for the default control endpoint, which always resides in address 0. This is
			 *  defined for convenience to give more readable code when used with the endpoint macros.
			 */
99
			#define ENDPOINT_CONTROLEP                    0
100
101

			#if (!defined(FIXED_CONTROL_ENDPOINT_SIZE) || defined(__DOXYGEN__))
102
103
104
				/** Default size of the default control endpoint's bank, until altered by the Endpoint0Size value 
				 *  in the device descriptor. Not available if the FIXED_CONTROL_ENDPOINT_SIZE token is defined.
				 */
105
				#define ENDPOINT_CONTROLEP_DEFAULT_SIZE   8
106
107
108
109
110
			#endif
			
			/** Endpoint number mask, for masking against endpoint addresses to retrieve the endpoint's
			 *  numerical address in the device.
			 */
111
			#define ENDPOINT_EPNUM_MASK                   0x03
112
113
114
115

			/** Endpoint bank size mask, for masking against endpoint addresses to retrieve the endpoint's
			 *  bank size in the device.
			 */
116
			#define ENDPOINT_EPSIZE_MASK                  0x7FF
117
118
119
120
121
			
			/** Maximum size in bytes of a given endpoint.
			 *
			 *  \param n  Endpoint number, a value between 0 and (ENDPOINT_TOTAL_ENDPOINTS - 1)
			 */				
122
			#define ENDPOINT_MAX_SIZE(n)                  _ENDPOINT_GET_MAXSIZE(n)
123
124
125
126
127

			/** Indicates if the given endpoint supports double banking.
			 *
			 *  \param n  Endpoint number, a value between 0 and (ENDPOINT_TOTAL_ENDPOINTS - 1)
			 */				
128
			#define ENDPOINT_DOUBLEBANK_SUPPORTED(n)      _ENDPOINT_GET_DOUBLEBANK(n)
129

130
131
132
133
134
135
136
137
138
139
			#if !defined(CONTROL_ONLY_DEVICE)
				#if defined(USB_FULL_CONTROLLER) || defined(USB_MODIFIED_FULL_CONTROLLER) || defined(__DOXYGEN__)
					/** Total number of endpoints (including the default control endpoint at address 0) which may
					 *  be used in the device. Different USB AVR models support different amounts of endpoints,
					 *  this value reflects the maximum number of endpoints for the currently selected AVR model.
					 */
					#define ENDPOINT_TOTAL_ENDPOINTS          7
				#else
					#define ENDPOINT_TOTAL_ENDPOINTS          5			
				#endif
140
			#else
141
				#define ENDPOINT_TOTAL_ENDPOINTS              1
142
143
			#endif
			
144
		/* Pseudo-Function Macros: */
145
146
147
148
149
150
151
152
153
154
155
			#if defined(__DOXYGEN__)
				/** Indicates the number of bytes currently stored in the current endpoint's selected bank.
				 *
				 *  \note The return width of this function may differ, depending on the maximum endpoint bank size
				 *        of the selected AVR model.
				 *
				 *  \ingroup Group_EndpointRW
				 *
				 *  \return Total number of bytes in the currently selected Endpoint's FIFO buffer
				 */
				static inline uint16_t Endpoint_BytesInEndpoint(void);
156
			
157
158
159
160
161
162
163
164
165
				/** Get the endpoint address of the currently selected endpoint. This is typically used to save
				 *  the currently selected endpoint number so that it can be restored after another endpoint has
				 *  been manipulated.
				 *
				 *  \return Index of the currently selected endpoint
				 */
				static inline uint8_t Endpoint_GetCurrentEndpoint(void);
				
				/** Selects the given endpoint number. If the address from the device descriptors is used, the
166
				 *  value should be masked with the \ref ENDPOINT_EPNUM_MASK constant to extract only the endpoint
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
				 *  number (and discarding the endpoint direction bit).
				 *
				 *  Any endpoint operations which do not require the endpoint number to be indicated will operate on
				 *  the currently selected endpoint.
				 *
				 *  \param EndpointNumber Endpoint number to select
				 */
				static inline void Endpoint_SelectEndpoint(uint8_t EndpointNumber);
				
				/** Resets the endpoint bank FIFO. This clears all the endpoint banks and resets the USB controller's
				 *  In and Out pointers to the bank's contents.
				 *
				 *  \param EndpointNumber Endpoint number whose FIFO buffers are to be reset
				 */
				static inline void Endpoint_ResetFIFO(uint8_t EndpointNumber);
				
				/** Enables the currently selected endpoint so that data can be sent and received through it to
				 *  and from a host.
				 *
186
				 *  \note Endpoints must first be configured properly via \ref Endpoint_ConfigureEndpoint().
187
188
				 */
				static inline void Endpoint_EnableEndpoint(void);
189

190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
				/** Disables the currently selected endpoint so that data cannot be sent and received through it
				 *  to and from a host.
				 */
				static inline void Endpoint_DisableEndpoint(void);
				
				/** Determines if the currently selected endpoint is enabled, but not necessarily configured.
				 *
				 * \return Boolean True if the currently selected endpoint is enabled, false otherwise
				 */
				static inline bool Endpoint_IsEnabled(void);
				
				/** Determines if the currently selected endpoint may be read from (if data is waiting in the endpoint
				 *  bank and the endpoint is an OUT direction, or if the bank is not yet full if the endpoint is an IN
				 *  direction). This function will return false if an error has occurred in the endpoint, if the endpoint
				 *  is an OUT direction and no packet (or an empty packet) has been received, or if the endpoint is an IN
				 *  direction and the endpoint bank is full.
				 *
				 *  \ingroup Group_EndpointPacketManagement
				 *
				 *  \return Boolean true if the currently selected endpoint may be read from or written to, depending on its direction
				 */
				static inline bool Endpoint_IsReadWriteAllowed(void);
				
				/** Determines if the currently selected endpoint is configured.
				 *
				 *  \return Boolean true if the currently selected endpoint has been configured, false otherwise
				 */
				static inline bool Endpoint_IsConfigured(void);
				
				/** Returns a mask indicating which INTERRUPT type endpoints have interrupted - i.e. their
				 *  interrupt duration has elapsed. Which endpoints have interrupted can be determined by
				 *  masking the return value against (1 << {Endpoint Number}).
				 *
				 *  \return Mask whose bits indicate which endpoints have interrupted
				 */
				static inline uint8_t Endpoint_GetEndpointInterrupts(void);
				
				/** Determines if the specified endpoint number has interrupted (valid only for INTERRUPT type
				 *  endpoints).
				 *
				 *  \param EndpointNumber  Index of the endpoint whose interrupt flag should be tested
				 *
				 *  \return Boolean true if the specified endpoint has interrupted, false otherwise
				 */
				static inline bool Endpoint_HasEndpointInterrupted(uint8_t EndpointNumber);
				
				/** Determines if the selected IN endpoint is ready for a new packet.
				 *
				 *  \ingroup Group_EndpointPacketManagement
				 *
				 *  \return Boolean true if the current endpoint is ready for an IN packet, false otherwise.
				 */
				static inline bool Endpoint_IsINReady(void);
				
				/** Determines if the selected OUT endpoint has received new packet.
				 *
				 *  \ingroup Group_EndpointPacketManagement
				 *
				 *  \return Boolean true if current endpoint is has received an OUT packet, false otherwise.
				 */
				static inline bool Endpoint_IsOUTReceived(void);
				
				/** Determines if the current CONTROL type endpoint has received a SETUP packet.
				 *
				 *  \ingroup Group_EndpointPacketManagement
				 *
				 *  \return Boolean true if the selected endpoint has received a SETUP packet, false otherwise.
				 */
				static inline bool Endpoint_IsSETUPReceived(void);
				
				/** Clears a received SETUP packet on the currently selected CONTROL type endpoint, freeing up the
				 *  endpoint for the next packet.
				 *
				 *  \ingroup Group_EndpointPacketManagement
				 *
				 *  \note This is not applicable for non CONTROL type endpoints.			 
				 */
267
				static inline void Endpoint_ClearSETUP(void);
268
				
269
270
				/** Sends an IN packet to the host on the currently selected endpoint, freeing up the endpoint for the
				 *  next packet and switching to the alternative endpoint bank if double banked.
271
272
273
274
275
				 *
				 *  \ingroup Group_EndpointPacketManagement
				 */
				static inline void Endpoint_ClearIN(void);
				
276
277
				/** Acknowledges an OUT packet to the host on the currently selected endpoint, freeing up the endpoint
				 *  for the next packet and switching to the alternative endpoint bank if double banked.
278
279
280
281
282
283
284
285
286
287
				 *
				 *  \ingroup Group_EndpointPacketManagement
				 */
				static inline void Endpoint_ClearOUT(void);
				
				/** Stalls the current endpoint, indicating to the host that a logical problem occurred with the
				 *  indicated endpoint and that the current transfer sequence should be aborted. This provides a
				 *  way for devices to indicate invalid commands to the host so that the current transfer can be
				 *  aborted and the host can begin its own recovery sequence.
				 *
288
				 *  The currently selected endpoint remains stalled until either the \ref Endpoint_ClearStall() macro
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
				 *  is called, or the host issues a CLEAR FEATURE request to the device for the currently selected
				 *  endpoint.
				 *
				 *  \ingroup Group_EndpointPacketManagement
				 */
				static inline void Endpoint_StallTransaction(void);
				
				/** Clears the STALL condition on the currently selected endpoint.
				 *
				 *  \ingroup Group_EndpointPacketManagement
				 */
				static inline void Endpoint_ClearStall(void);
				
				/** Determines if the currently selected endpoint is stalled, false otherwise.
				 *
				 *  \ingroup Group_EndpointPacketManagement
				 *
				 *  \return Boolean true if the currently selected endpoint is stalled, false otherwise
				 */
				static inline bool Endpoint_IsStalled(void);
				
				/** Resets the data toggle of the currently selected endpoint. */
				static inline void Endpoint_ResetDataToggle(void);
				
				/** Determines the currently selected endpoint's direction.
				 *
				 *  \return The currently selected endpoint's direction, as a ENDPOINT_DIR_* mask.
				 */
				static inline uint8_t Endpoint_GetEndpointDirection(void);
			#else
				#if defined(USB_FULL_CONTROLLER) || defined(USB_MODIFIED_FULL_CONTROLLER) || defined(__DOXYGEN__)
					#define Endpoint_BytesInEndpoint()        UEBCX
				#else
					#define Endpoint_BytesInEndpoint()        UEBCLX
				#endif
				
325
326
327
328
329
				#if !defined(CONTROL_ONLY_DEVICE)
					#define Endpoint_GetCurrentEndpoint()     (UENUM & ENDPOINT_EPNUM_MASK)
				#else
					#define Endpoint_GetCurrentEndpoint()     ENDPOINT_CONTROLEP
				#endif
330
				
331
332
333
334
335
				#if !defined(CONTROL_ONLY_DEVICE)
					#define Endpoint_SelectEndpoint(epnum)    MACROS{ UENUM = epnum; }MACROE
				#else
					#define Endpoint_SelectEndpoint(epnum)    (void)epnum
				#endif
336

337
				#define Endpoint_ResetFIFO(epnum)             MACROS{ UERST = (1 << epnum); UERST = 0; }MACROE
338

339
				#define Endpoint_EnableEndpoint()             MACROS{ UECONX |= (1 << EPEN); }MACROE
340

341
				#define Endpoint_DisableEndpoint()            MACROS{ UECONX &= ~(1 << EPEN); }MACROE
342

343
				#define Endpoint_IsEnabled()                  ((UECONX & (1 << EPEN)) ? true : false)
344

345
346
347
348
				#if !defined(CONTROL_ONLY_DEVICE)
					#define Endpoint_IsReadWriteAllowed()     ((UEINTX & (1 << RWAL)) ? true : false)
				#endif
				
349
				#define Endpoint_IsConfigured()               ((UESTA0X & (1 << CFGOK)) ? true : false)
350

351
				#define Endpoint_GetEndpointInterrupts()      UEINT
352

353
354
				#define Endpoint_HasEndpointInterrupted(n)    ((UEINT & (1 << n)) ? true : false)
				
355
				#define Endpoint_IsINReady()                  ((UEINTX & (1 << TXINI))  ? true : false)
356
				
357
				#define Endpoint_IsOUTReceived()              ((UEINTX & (1 << RXOUTI)) ? true : false)
358

359
				#define Endpoint_IsSETUPReceived()            ((UEINTX & (1 << RXSTPI)) ? true : false)
360

361
				#define Endpoint_ClearSETUP()                 MACROS{ UEINTX &= ~(1 << RXSTPI); }MACROE
362

363
364
365
366
367
368
				#if !defined(CONTROL_ONLY_DEVICE)
					#define Endpoint_ClearIN()                MACROS{ uint8_t Temp = UEINTX; UEINTX = (Temp & ~(1 << TXINI)); \
					                                                  UEINTX = (Temp & ~(1 << FIFOCON)); }MACROE
				#else
					#define Endpoint_ClearIN()                MACROS{ UEINTX &= ~(1 << TXINI); }MACROE
				#endif
369

370
371
372
373
374
375
				#if !defined(CONTROL_ONLY_DEVICE)
					#define Endpoint_ClearOUT()               MACROS{ uint8_t Temp = UEINTX; UEINTX = (Temp & ~(1 << RXOUTI)); \
					                                                  UEINTX = (Temp & ~(1 << FIFOCON)); }MACROE
				#else
					#define Endpoint_ClearOUT()               MACROS{ UEINTX &= ~(1 << RXOUTI); }MACROE			
				#endif
376

377
				#define Endpoint_StallTransaction()           MACROS{ UECONX |= (1 << STALLRQ); }MACROE
378

379
				#define Endpoint_ClearStall()                 MACROS{ UECONX |= (1 << STALLRQC); }MACROE
380

381
382
383
384
385
386
				#define Endpoint_IsStalled()                  ((UECONX & (1 << STALLRQ)) ? true : false)

				#define Endpoint_ResetDataToggle()            MACROS{ UECONX |= (1 << RSTDT); }MACROE
				
				#define Endpoint_GetEndpointDirection()       (UECFG0X & ENDPOINT_DIR_IN)
			#endif
387
388

		/* Enums: */
389
			/** Enum for the possible error return codes of the \ref Endpoint_WaitUntilReady() function.
390
391
392
			 *
			 *  \ingroup Group_EndpointRW
			 */
393
394
395
396
397
398
399
400
401
402
403
			enum Endpoint_WaitUntilReady_ErrorCodes_t
			{
				ENDPOINT_READYWAIT_NoError                 = 0, /**< Endpoint is ready for next packet, no error. */
				ENDPOINT_READYWAIT_EndpointStalled         = 1, /**< The endpoint was stalled during the stream
				                                                 *   transfer by the host or device.
				                                                 */
				ENDPOINT_READYWAIT_DeviceDisconnected      = 2,	/**< Device was disconnected from the host while
				                                                 *   waiting for the endpoint to become ready.
				                                                 */	
				ENDPOINT_READYWAIT_Timeout                 = 3, /**< The host failed to accept or send the next packet
				                                                 *   within the software timeout period set by the
404
				                                                 *   \ref USB_STREAM_TIMEOUT_MS macro.
405
406
407
				                                                 */
			};
		
408
409
410
411
			/** Enum for the possible error return codes of the Endpoint_*_Stream_* functions.
			 *
			 *  \ingroup Group_EndpointRW
			 */
412
413
			enum Endpoint_Stream_RW_ErrorCodes_t
			{
414
415
416
417
418
419
420
421
422
423
424
425
426
427
				ENDPOINT_RWSTREAM_NoError            = 0, /**< Command completed successfully, no error. */
				ENDPOINT_RWSTREAM_EndpointStalled    = 1, /**< The endpoint was stalled during the stream
				                                           *   transfer by the host or device.
				                                           */
				ENDPOINT_RWSTREAM_DeviceDisconnected = 1, /**< Device was disconnected from the host during
				                                           *   the transfer.
				                                           */
				ENDPOINT_RWSTREAM_Timeout            = 2, /**< The host failed to accept or send the next packet
				                                           *   within the software timeout period set by the
				                                           *   \ref USB_STREAM_TIMEOUT_MS macro.
				                                           */
				ENDPOINT_RWSTREAM_CallbackAborted    = 3, /**< Indicates that the stream's callback function
			                                               *   aborted the transfer early.
				                                           */
428
429
			};
			
430
431
432
433
			/** Enum for the possible error return codes of the Endpoint_*_Control_Stream_* functions..
			 *
			 *  \ingroup Group_EndpointRW
			 */
434
435
			enum Endpoint_ControlStream_RW_ErrorCodes_t
			{
436
437
				ENDPOINT_RWCSTREAM_NoError            = 0, /**< Command completed successfully, no error. */
				ENDPOINT_RWCSTREAM_HostAborted        = 1, /**< The aborted the transfer prematurely. */
438
439
440
			};

		/* Inline Functions: */
441
442
443
444
445
446
			/** Reads one byte from the currently selected endpoint's bank, for OUT direction endpoints.
			 *
			 *  \ingroup Group_EndpointRW
			 *
			 *  \return Next byte in the currently selected endpoint's FIFO buffer
			 */
447
			static inline uint8_t Endpoint_Read_Byte(void) ATTR_WARN_UNUSED_RESULT ATTR_ALWAYS_INLINE;
448
449
450
451
452
			static inline uint8_t Endpoint_Read_Byte(void)
			{
				return UEDATX;
			}

453
454
455
456
457
458
			/** Writes one byte from the currently selected endpoint's bank, for IN direction endpoints.
			 *
			 *  \ingroup Group_EndpointRW
			 *
			 *  \param Byte  Next byte to write into the the currently selected endpoint's FIFO buffer
			 */
459
			static inline void Endpoint_Write_Byte(const uint8_t Byte) ATTR_ALWAYS_INLINE;
460
461
462
463
464
			static inline void Endpoint_Write_Byte(const uint8_t Byte)
			{
				UEDATX = Byte;
			}

465
466
467
468
			/** Discards one byte from the currently selected endpoint's bank, for OUT direction endpoints.
			 *
			 *  \ingroup Group_EndpointRW
			 */
469
			static inline void Endpoint_Discard_Byte(void) ATTR_ALWAYS_INLINE;
470
471
472
473
474
475
476
477
478
			static inline void Endpoint_Discard_Byte(void)
			{
				uint8_t Dummy;
				
				Dummy = UEDATX;
			}
			
			/** Reads two bytes from the currently selected endpoint's bank in little endian format, for OUT
			 *  direction endpoints.
479
480
481
482
			 *
			 *  \ingroup Group_EndpointRW
			 *
			 *  \return Next word in the currently selected endpoint's FIFO buffer
483
			 */
484
			static inline uint16_t Endpoint_Read_Word_LE(void) ATTR_WARN_UNUSED_RESULT ATTR_ALWAYS_INLINE;
485
486
487
488
489
490
491
492
493
494
495
496
			static inline uint16_t Endpoint_Read_Word_LE(void)
			{
				uint16_t Data;
				
				Data  = UEDATX;
				Data |= (((uint16_t)UEDATX) << 8);
			
				return Data;
			}

			/** Reads two bytes from the currently selected endpoint's bank in big endian format, for OUT
			 *  direction endpoints.
497
498
499
500
			 *
			 *  \ingroup Group_EndpointRW
			 *
			 *  \return Next word in the currently selected endpoint's FIFO buffer
501
			 */
502
			static inline uint16_t Endpoint_Read_Word_BE(void) ATTR_WARN_UNUSED_RESULT ATTR_ALWAYS_INLINE;
503
504
505
506
507
508
509
510
511
512
513
514
			static inline uint16_t Endpoint_Read_Word_BE(void)
			{
				uint16_t Data;
				
				Data  = (((uint16_t)UEDATX) << 8);
				Data |= UEDATX;
			
				return Data;
			}

			/** Writes two bytes to the currently selected endpoint's bank in little endian format, for IN
			 *  direction endpoints.
515
516
517
518
			 *
			 *  \ingroup Group_EndpointRW
			 *
			 *  \param Word  Next word to write to the currently selected endpoint's FIFO buffer
519
			 */
520
			static inline void Endpoint_Write_Word_LE(const uint16_t Word) ATTR_ALWAYS_INLINE;
521
522
523
524
525
526
527
528
			static inline void Endpoint_Write_Word_LE(const uint16_t Word)
			{
				UEDATX = (Word & 0xFF);
				UEDATX = (Word >> 8);
			}
			
			/** Writes two bytes to the currently selected endpoint's bank in big endian format, for IN
			 *  direction endpoints.
529
530
531
532
			 *
			 *  \ingroup Group_EndpointRW
			 *
			 *  \param Word  Next word to write to the currently selected endpoint's FIFO buffer
533
			 */
534
			static inline void Endpoint_Write_Word_BE(const uint16_t Word) ATTR_ALWAYS_INLINE;
535
536
537
538
539
540
			static inline void Endpoint_Write_Word_BE(const uint16_t Word)
			{
				UEDATX = (Word >> 8);
				UEDATX = (Word & 0xFF);
			}

541
542
543
544
			/** Discards two bytes from the currently selected endpoint's bank, for OUT direction endpoints.
			 *
			 *  \ingroup Group_EndpointRW
			 */
545
			static inline void Endpoint_Discard_Word(void) ATTR_ALWAYS_INLINE;
546
547
548
549
550
551
552
553
554
555
			static inline void Endpoint_Discard_Word(void)
			{
				uint8_t Dummy;
				
				Dummy = UEDATX;
				Dummy = UEDATX;
			}

			/** Reads four bytes from the currently selected endpoint's bank in little endian format, for OUT
			 *  direction endpoints.
556
557
558
559
			 *
			 *  \ingroup Group_EndpointRW
			 *
			 *  \return Next double word in the currently selected endpoint's FIFO buffer
560
			 */
561
			static inline uint32_t Endpoint_Read_DWord_LE(void) ATTR_WARN_UNUSED_RESULT ATTR_ALWAYS_INLINE;
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
			static inline uint32_t Endpoint_Read_DWord_LE(void)
			{
				union
				{
					uint32_t DWord;
					uint8_t  Bytes[4];
				} Data;
				
				Data.Bytes[0] = UEDATX;
				Data.Bytes[1] = UEDATX;
				Data.Bytes[2] = UEDATX;
				Data.Bytes[3] = UEDATX;
			
				return Data.DWord;
			}

			/** Reads four bytes from the currently selected endpoint's bank in big endian format, for OUT
			 *  direction endpoints.
580
581
582
583
			 *
			 *  \ingroup Group_EndpointRW
			 *
			 *  \return Next double word in the currently selected endpoint's FIFO buffer
584
			 */
585
			static inline uint32_t Endpoint_Read_DWord_BE(void) ATTR_WARN_UNUSED_RESULT ATTR_ALWAYS_INLINE;
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
			static inline uint32_t Endpoint_Read_DWord_BE(void)
			{
				union
				{
					uint32_t DWord;
					uint8_t  Bytes[4];
				} Data;
				
				Data.Bytes[3] = UEDATX;
				Data.Bytes[2] = UEDATX;
				Data.Bytes[1] = UEDATX;
				Data.Bytes[0] = UEDATX;
			
				return Data.DWord;
			}

			/** Writes four bytes to the currently selected endpoint's bank in little endian format, for IN
			 *  direction endpoints.
604
605
606
607
			 *
			 *  \ingroup Group_EndpointRW
			 *
			 *  \param DWord  Next double word to write to the currently selected endpoint's FIFO buffer
608
			 */
609
			static inline void Endpoint_Write_DWord_LE(const uint32_t DWord) ATTR_ALWAYS_INLINE;
610
611
			static inline void Endpoint_Write_DWord_LE(const uint32_t DWord)
			{
612
613
614
615
				UEDATX = (DWord &  0xFF);
				UEDATX = (DWord >> 8);
				UEDATX = (DWord >> 16);
				UEDATX = (DWord >> 24);
616
617
618
619
			}
			
			/** Writes four bytes to the currently selected endpoint's bank in big endian format, for IN
			 *  direction endpoints.
620
621
622
623
			 *
			 *  \ingroup Group_EndpointRW
			 *
			 *  \param DWord  Next double word to write to the currently selected endpoint's FIFO buffer
624
			 */
625
			static inline void Endpoint_Write_DWord_BE(const uint32_t DWord) ATTR_ALWAYS_INLINE;
626
627
			static inline void Endpoint_Write_DWord_BE(const uint32_t DWord)
			{
628
629
630
631
				UEDATX = (DWord >> 24);
				UEDATX = (DWord >> 16);
				UEDATX = (DWord >> 8);
				UEDATX = (DWord &  0xFF);
632
633
			}

634
635
636
637
			/** Discards four bytes from the currently selected endpoint's bank, for OUT direction endpoints.	
			 *
			 *  \ingroup Group_EndpointRW
			 */
638
			static inline void Endpoint_Discard_DWord(void) ATTR_ALWAYS_INLINE;
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
			static inline void Endpoint_Discard_DWord(void)
			{
				uint8_t Dummy;
				
				Dummy = UEDATX;
				Dummy = UEDATX;
				Dummy = UEDATX;
				Dummy = UEDATX;
			}

		/* External Variables: */
			/** Global indicating the maximum packet size of the default control endpoint located at address
			 *  0 in the device. This value is set to the value indicated in the device descriptor in the user
			 *  project once the USB interface is initialized into device mode.
			 *
			 *  If space is an issue, it is possible to fix this to a static value by defining the control
			 *  endpoint size in the FIXED_CONTROL_ENDPOINT_SIZE token passed to the compiler in the makefile
			 *  via the -D switch. When a fixed control endpoint size is used, the size is no longer dynamically
			 *  read from the descriptors at runtime and instead fixed to the given value. When used, it is
			 *  important that the descriptor control endpoint size value matches the size given as the
			 *  FIXED_CONTROL_ENDPOINT_SIZE token - it is recommended that the FIXED_CONTROL_ENDPOINT_SIZE token
			 *  be used in the descriptors to ensure this.
			 *
			 *  \note This variable should be treated as read-only in the user application, and never manually
			 *        changed in value.
			 */
			#if (!defined(FIXED_CONTROL_ENDPOINT_SIZE) || defined(__DOXYGEN__))
				extern uint8_t USB_ControlEndpointSize;
			#else
				#define USB_ControlEndpointSize FIXED_CONTROL_ENDPOINT_SIZE
			#endif

		/* Function Prototypes: */
			/** Configures the specified endpoint number with the given endpoint type, direction, bank size
			 *  and banking mode. Endpoints should be allocated in ascending order by their address in the
			 *  device (i.e. endpoint 1 should be configured before endpoint 2 and so on).
			 *
			 *  The endpoint type may be one of the EP_TYPE_* macros listed in LowLevel.h and the direction
677
			 *  may be either \ref ENDPOINT_DIR_OUT or \ref ENDPOINT_DIR_IN.
678
679
680
681
682
			 *
			 *  The bank size must indicate the maximum packet size that the endpoint can handle. Different
			 *  endpoint numbers can handle different maximum packet sizes - refer to the chosen USB AVR's
			 *  datasheet to determine the maximum bank size for each endpoint.
			 *
683
			 *  The banking mode may be either \ref ENDPOINT_BANK_SINGLE or \ref ENDPOINT_BANK_DOUBLE.
684
			 *
685
			 *  The success of this routine can be determined via the \ref Endpoint_IsConfigured() macro.
686
687
688
689
690
691
692
693
694
			 *
			 *  \note This routine will select the specified endpoint, and the endpoint will remain selected
			 *        once the routine completes regardless of if the endpoint configuration succeeds.
			 *
			 *  \return Boolean true if the configuration succeeded, false otherwise
			 */
			bool Endpoint_ConfigureEndpoint(const uint8_t  Number, const uint8_t Type, const uint8_t Direction,
			                                const uint16_t Size, const uint8_t Banks);

695
696
			#if !defined(CONTROL_ONLY_DEVICE)

697
698
699
700
701
			/** Spinloops until the currently selected non-control endpoint is ready for the next packet of data
			 *  to be read or written to it.
			 *
			 *  \note This routine should not be called on CONTROL type endpoints.
			 *
702
703
			 *  \ingroup Group_EndpointRW
			 *
704
			 *  \return A value from the \ref Endpoint_WaitUntilReady_ErrorCodes_t enum.
705
706
707
708
709
710
			 */
			uint8_t Endpoint_WaitUntilReady(void);

			/** Reads and discards the given number of bytes from the endpoint from the given buffer,
			 *  discarding fully read packets from the host as needed. The last packet is not automatically
			 *  discarded once the remaining bytes has been read; the user is responsible for manually
711
			 *  discarding the last packet from the host via the \ref Endpoint_ClearOUT() macro. Between
712
713
714
			 *  each USB packet, the given stream callback function is executed repeatedly until the next
			 *  packet is ready, allowing for early aborts of stream transfers.
			 *
715
			 *	The callback routine should be created using the \ref STREAM_CALLBACK() macro. If the token
716
			 *  NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are disabled
717
			 *  and this function has the Callback parameter omitted.
718
719
720
			 *
			 *  \note This routine should not be used on CONTROL type endpoints.
			 *
721
722
			 *  \ingroup Group_EndpointRW
			 *
723
			 *  \param Length    Number of bytes to send via the currently selected endpoint.
724
			 *  \param Callback  Name of a callback routine to call between successive USB packet transfers, NULL if no callback
725
			 *
726
			 *  \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
727
728
729
			 */
			uint8_t Endpoint_Discard_Stream(uint16_t Length
			#if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)
730
			                                , StreamCallbackPtr_t Callback
731
732
733
734
735
736
			#endif
			                                );

			/** Writes the given number of bytes to the endpoint from the given buffer in little endian,
			 *  sending full packets to the host as needed. The last packet filled is not automatically sent;
			 *  the user is responsible for manually sending the last written packet to the host via the
737
			 *  \ref Endpoint_ClearIN() macro. Between each USB packet, the given stream callback function
738
739
740
			 *  is executed repeatedly until the endpoint is ready to accept the next packet, allowing for early
			 *  aborts of stream transfers.
			 *
741
			 *	The callback routine should be created using the \ref STREAM_CALLBACK() macro. If the token
742
			 *  NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are disabled
743
			 *  and this function has the Callback parameter omitted.
744
745
746
			 *
			 *  \note This routine should not be used on CONTROL type endpoints.
			 *
747
748
			 *  \ingroup Group_EndpointRW
			 *
749
750
			 *  \param Buffer    Pointer to the source data buffer to read from.
			 *  \param Length    Number of bytes to read for the currently selected endpoint into the buffer.
751
			 *  \param Callback  Name of a callback routine to call between successive USB packet transfers, NULL if no callback
752
			 *
753
			 *  \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
754
755
756
			 */
			uint8_t Endpoint_Write_Stream_LE(const void* Buffer, uint16_t Length
			#if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)
757
			                                 , StreamCallbackPtr_t Callback
758
759
760
761
762
763
			#endif
			                                 ) ATTR_NON_NULL_PTR_ARG(1);

			/** Writes the given number of bytes to the endpoint from the given buffer in big endian,
			 *  sending full packets to the host as needed. The last packet filled is not automatically sent;
			 *  the user is responsible for manually sending the last written packet to the host via the
764
			 *  \ref Endpoint_ClearIN() macro. Between each USB packet, the given stream callback function
765
766
767
			 *  is executed repeatedly until the endpoint is ready to accept the next packet, allowing for early
			 *  aborts of stream transfers.
			 *
768
			 *	The callback routine should be created using the \ref STREAM_CALLBACK() macro. If the token
769
			 *  NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are disabled
770
			 *  and this function has the Callback parameter omitted.
771
772
773
			 *
			 *  \note This routine should not be used on CONTROL type endpoints.
			 *
774
775
			 *  \ingroup Group_EndpointRW
			 *
776
777
			 *  \param Buffer    Pointer to the source data buffer to read from.
			 *  \param Length    Number of bytes to read for the currently selected endpoint into the buffer.
778
			 *  \param Callback  Name of a callback routine to call between successive USB packet transfers, NULL if no callback
779
			 *
780
			 *  \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
781
782
783
			 */
			uint8_t Endpoint_Write_Stream_BE(const void* Buffer, uint16_t Length
			#if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)
784
			                                 , StreamCallbackPtr_t Callback
785
786
787
788
789
790
			#endif
			                                 ) ATTR_NON_NULL_PTR_ARG(1);

			/** Reads the given number of bytes from the endpoint from the given buffer in little endian,
			 *  discarding fully read packets from the host as needed. The last packet is not automatically
			 *  discarded once the remaining bytes has been read; the user is responsible for manually
791
			 *  discarding the last packet from the host via the \ref Endpoint_ClearOUT() macro. Between
792
793
794
			 *  each USB packet, the given stream callback function is executed repeatedly until the endpoint
			 *  is ready to accept the next packet, allowing for early aborts of stream transfers.
			 *
795
			 *	The callback routine should be created using the \ref STREAM_CALLBACK() macro. If the token
796
			 *  NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are disabled
797
			 *  and this function has the Callback parameter omitted.
798
799
800
			 *
			 *  \note This routine should not be used on CONTROL type endpoints.
			 *
801
802
			 *  \ingroup Group_EndpointRW
			 *
803
804
			 *  \param Buffer    Pointer to the destination data buffer to write to.
			 *  \param Length    Number of bytes to send via the currently selected endpoint.
805
			 *  \param Callback  Name of a callback routine to call between successive USB packet transfers, NULL if no callback
806
			 *
807
			 *  \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
808
809
810
			 */
			uint8_t Endpoint_Read_Stream_LE(void* Buffer, uint16_t Length
			#if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)
811
			                                , StreamCallbackPtr_t Callback
812
813
814
815
816
817
			#endif
			                                ) ATTR_NON_NULL_PTR_ARG(1);

			/** Reads the given number of bytes from the endpoint from the given buffer in big endian,
			 *  discarding fully read packets from the host as needed. The last packet is not automatically
			 *  discarded once the remaining bytes has been read; the user is responsible for manually
818
			 *  discarding the last packet from the host via the \ref Endpoint_ClearOUT() macro. Between
819
820
821
			 *  each USB packet, the given stream callback function is executed repeatedly until the endpoint
			 *  is ready to accept the next packet, allowing for early aborts of stream transfers.
			 *
822
			 *	The callback routine should be created using the \ref STREAM_CALLBACK() macro. If the token
823
			 *  NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are disabled
824
			 *  and this function has the Callback parameter omitted.
825
826
827
			 *
			 *  \note This routine should not be used on CONTROL type endpoints.
			 *
828
829
			 *  \ingroup Group_EndpointRW
			 *
830
831
			 *  \param Buffer    Pointer to the destination data buffer to write to.
			 *  \param Length    Number of bytes to send via the currently selected endpoint.
832
			 *  \param Callback  Name of a callback routine to call between successive USB packet transfers, NULL if no callback
833
			 *
834
			 *  \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
835
836
837
			 */
			uint8_t Endpoint_Read_Stream_BE(void* Buffer, uint16_t Length
			#if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)
838
			                                , StreamCallbackPtr_t Callback
839
840
841
			#endif
			                                ) ATTR_NON_NULL_PTR_ARG(1);

842
843
			#endif

844
			/** Writes the given number of bytes to the CONTROL type endpoint from the given buffer in little endian,
845
			 *  sending full packets to the host as needed. The host OUT acknowledgement is not automatically cleared
846
			 *  in both failure and success states; the user is responsible for manually clearing the setup OUT to
847
			 *  finalize the transfer via the \ref Endpoint_ClearOUT() macro.
848
849
850
851
852
853
			 *
			 *  \note This routine should only be used on CONTROL type endpoints.
			 *
			 *  \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
			 *           together; i.e. the entire stream data must be read or written at the one time.
			 *
854
855
			 *  \ingroup Group_EndpointRW
			 *
856
857
858
			 *  \param Buffer  Pointer to the source data buffer to read from.
			 *  \param Length  Number of bytes to read for the currently selected endpoint into the buffer.
			 *
859
			 *  \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
860
861
862
863
			 */
			uint8_t Endpoint_Write_Control_Stream_LE(const void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);

			/** Writes the given number of bytes to the CONTROL type endpoint from the given buffer in big endian,
864
			 *  sending full packets to the host as needed. The host OUT acknowledgement is not automatically cleared
865
			 *  in both failure and success states; the user is responsible for manually clearing the setup OUT to
866
			 *  finalize the transfer via the \ref Endpoint_ClearOUT() macro.
867
868
869
870
871
872
			 *
			 *  \note This routine should only be used on CONTROL type endpoints.
			 *
			 *  \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
			 *           together; i.e. the entire stream data must be read or written at the one time.
			 *
873
874
			 *  \ingroup Group_EndpointRW
			 *
875
876
877
			 *  \param Buffer  Pointer to the source data buffer to read from.
			 *  \param Length  Number of bytes to read for the currently selected endpoint into the buffer.
			 *
878
			 *  \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
879
880
881
882
			 */
			uint8_t Endpoint_Write_Control_Stream_BE(const void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);

			/** Reads the given number of bytes from the CONTROL endpoint from the given buffer in little endian,
883
			 *  discarding fully read packets from the host as needed. The device IN acknowledgement is not
884
			 *  automatically sent after success or failure states; the user is responsible for manually sending the
885
			 *  setup IN to finalize the transfer via the \ref Endpoint_ClearIN() macro.
886
887
888
889
890
891
			 *
			 *  \note This routine should only be used on CONTROL type endpoints.
			 *
			 *  \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
			 *           together; i.e. the entire stream data must be read or written at the one time.
			 *
892
893
			 *  \ingroup Group_EndpointRW
			 *
894
895
896
			 *  \param Buffer  Pointer to the destination data buffer to write to.
			 *  \param Length  Number of bytes to send via the currently selected endpoint.
			 *
897
			 *  \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
898
			 */
899
			uint8_t Endpoint_Read_Control_Stream_LE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
900
901

			/** Reads the given number of bytes from the CONTROL endpoint from the given buffer in big endian,
902
			 *  discarding fully read packets from the host as needed. The device IN acknowledgement is not
903
			 *  automatically sent after success or failure states; the user is responsible for manually sending the
904
			 *  setup IN to finalize the transfer via the \ref Endpoint_ClearIN() macro.
905
906
907
908
909
910
			 *
			 *  \note This routine should only be used on CONTROL type endpoints.
			 *
			 *  \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
			 *           together; i.e. the entire stream data must be read or written at the one time.
			 *
911
912
			 *  \ingroup Group_EndpointRW
			 *
913
914
915
			 *  \param Buffer  Pointer to the destination data buffer to write to.
			 *  \param Length  Number of bytes to send via the currently selected endpoint.
			 *
916
			 *  \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
917
			 */
918
			uint8_t Endpoint_Read_Control_Stream_BE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);		
919
920
921
922
			
	/* Private Interface - For use in library only: */
	#if !defined(__DOXYGEN__)
		/* Macros: */
923
924
			#define Endpoint_AllocateMemory()              MACROS{ UECFG1X |=  (1 << ALLOC); }MACROE
			#define Endpoint_DeallocateMemory()            MACROS{ UECFG1X &= ~(1 << ALLOC); }MACROE
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
			
			#define _ENDPOINT_GET_MAXSIZE(n)               _ENDPOINT_GET_MAXSIZE2(ENDPOINT_DETAILS_EP ## n)
			#define _ENDPOINT_GET_MAXSIZE2(details)        _ENDPOINT_GET_MAXSIZE3(details)
			#define _ENDPOINT_GET_MAXSIZE3(maxsize, db)    maxsize

			#define _ENDPOINT_GET_DOUBLEBANK(n)            _ENDPOINT_GET_DOUBLEBANK2(ENDPOINT_DETAILS_EP ## n)
			#define _ENDPOINT_GET_DOUBLEBANK2(details)     _ENDPOINT_GET_DOUBLEBANK3(details)
			#define _ENDPOINT_GET_DOUBLEBANK3(maxsize, db) db
			
			#if defined(USB_FULL_CONTROLLER) || defined(USB_MODIFIED_FULL_CONTROLLER)
				#define ENDPOINT_DETAILS_EP0               64,  true
				#define ENDPOINT_DETAILS_EP1               256, true
				#define ENDPOINT_DETAILS_EP2               64,  true
				#define ENDPOINT_DETAILS_EP3               64,  true
				#define ENDPOINT_DETAILS_EP4               64,  true
				#define ENDPOINT_DETAILS_EP5               64,  true
				#define ENDPOINT_DETAILS_EP6               64,  true
			#else
				#define ENDPOINT_DETAILS_EP0               64,  true
				#define ENDPOINT_DETAILS_EP1               64,  false
				#define ENDPOINT_DETAILS_EP2               64,  false
				#define ENDPOINT_DETAILS_EP3               64,  true
				#define ENDPOINT_DETAILS_EP4               64,  true			
			#endif

950
951
952
953
954
955
956
957
			#define Endpoint_ConfigureEndpoint(Number, Type, Direction, Size, Banks)            \
			                                    Endpoint_ConfigureEndpoint_Prv(Number,          \
			                                              ((Type << EPTYPE0) | Direction),      \
			                                              ((1 << ALLOC) | Banks |               \
			                                                (__builtin_constant_p(Size) ?       \
			                                                 Endpoint_BytesToEPSizeMask(Size) :  \
			                                                 Endpoint_BytesToEPSizeMaskDynamic(Size))))
													
958
		/* Function Prototypes: */
959
960
961
			void    Endpoint_ClearEndpoints(void);
			uint8_t Endpoint_BytesToEPSizeMaskDynamic(const uint16_t Size);
			bool    Endpoint_ConfigureEndpoint_Prv(const uint8_t Number, const uint8_t UECFG0XData, const uint8_t UECFG1XData);
962
963
			
		/* Inline Functions: */
964
			static inline uint8_t Endpoint_BytesToEPSizeMask(const uint16_t Bytes) ATTR_WARN_UNUSED_RESULT ATTR_CONST ATTR_ALWAYS_INLINE;
965
966
			static inline uint8_t Endpoint_BytesToEPSizeMask(const uint16_t Bytes)
			{
967
968
969
970
971
972
973
974
975
976
				uint8_t  MaskVal    = 0;
				uint16_t CheckBytes = 8;
				
				while (CheckBytes < Bytes)
				{
					MaskVal++;
					CheckBytes <<= 1;
				}
				
				return (MaskVal << EPSIZE0);
977
978
979
980
981
982
983
984
985
986
			};

	#endif

	/* Disable C linkage for C++ Compilers: */
		#if defined(__cplusplus)
			}
		#endif
		
#endif
987
988

/** @} */