Commit 002f4243 authored by Nikhil Lal's avatar Nikhil Lal

Update oxidizer/readme.md

parent 63a31b5d
Initial evaluation of oxidizer method for sterilization
This category can be divided into two main categories: methods vaporizing then heating a liquid, e.g. H2O2, and plasmification of gas directly. A system that has inputs only consisting of air and electricity would be the ideal scenario as it means it would function without the challenges of a liquid supply chain.
Before proceeding down a path to build any sterilization system there needs to be a biological or virological indicator that can be used as a control. The indicator Geobacillus stearothermophilus spores (Botelho-Almeida 2008) were used in a few different studies due to their stericidal resistance. 3m has a (flourescent tagged version)[https://multimedia.3m.com/mws/media/497747O/attest-rrbi-for-steam-1292-package-insert-english.pdf] which may prove useful for this purpose.
to be continued...
prior art:
[Apparatus And Method For Using Ozone As A Disinfectant](https://patents.google.com/patent/US20120020830A1/en)
[Development of a Practical Method for Using Ozone Gas as a Virus Decontaminating Agent](https://www.tandfonline.com/doi/full/10.1080/01919510902747969?src=recsys)
[Evaluating the Potential, Applicability, and Effectiveness of Ozone Sterilization Process for Medical Devices](https://link.springer.com/article/10.1007/s12247-017-9308-7)